User`s manual
Spyder 3 GigE User’s Manual
DALSA 03-032-10158-09
101
Mnemonic Syntax Parameters
Description
set baud rate
sbr
i
Set the speed of camera serial
communication port. Baud rates:
9600,
19200, 57600, and 115200. Default:
9600.
set ccd direction
scd
i
Sets the CCD shift direction where:
0 = Forward CCD shift direction.
1 = Reverse CCD shift direction.
2 = Externally controlled direction
control via CC3.
set data mode
sdm
i
Sets the camera’s bit width where:
For SG-10-01K40 and SG-10-02K40
0 =
8 bits, 1 tap, 40MHz data rate
1 = 12 bits, 1 tap, 40MHz data rate
For SG-10-01K80 and SG-10-02K80
2
= 8 bits, 2 taps, 80Mhz data rate
3 = 12 bits, 2 taps, 80MHz data rate
set digital offset
sdo
t i
Subtracts the input value from the
video signal prior to FPN correction.
t = tap selection, either 1 or 2
depending on camera model, or
0 for
all taps.
i = Offset in a range from 0 to
2048DN.
set exposure mode
sem
m
Sets the exposure mode:
2 = Internal SYNC, internal PRIN,
programmable line rate and exposure
time using commands
ssf and set
3 = External SYNC, internal PRIN,
maximum exposure time
4 = Smart EXSYNC
5 = External SYNC and PRIN
6 = External SYNC, internal PRIN,
programmable exposure time
7 = Internal programmable SYNC,
maximum exposure time. Factory
setting.
8 = Internal SYNC, internal PRIN,
programmable exposure time.
Maximum line rate for exposure time.
set exposure time
set
f
Sets the exposure time. Refer to the
camera help screen (
h command) for
allowable range.
set fpn coeff
sfc
x i
Set the FPN coefficient.
x =pixel number within the range 1 to
sensor pixel count.
i= FPN value within the range 0 to
2047 (12-bit LSB).