Instructions on Using the Camera Scan Direction to Control
Camera Parameters
The camera is capable of adjusting camera parameters on-the-fly based on the scan direction of the
camera. These parameters include gain, flat field coefficients, white balance and exposure time.
1. The first step is to put the camera in the reverse direction. This can be done using a reverse
signal through CC3 and the Direction Source set to external or by having the Direction
Source set to Internal and the Internal Direction set to reverse.
2. Set up all the desired parameters, including flat field corrections.
3. Save the camera parameters to a User set other than the default user set.
First, setup parameters for the
reverse direction.