Black Level
Apply a digital addition after an FPN correction: ± 1/8 of available range. For
example in 12-bit mode the available range is -512 to +511.
Gain
Set the gain as an amplification factor applied to the video signal across all
pixels: 1x to 10x.
Set Image Size
To set the height of the image, and therefore the number of lines to scan, use the parameters grouped
under the Image Format Control set.
Image Format Control
Control the size of the transmitted image
Width
Width of the image. Read only.
Height
Height of the image in lines. Read only.
Pixel Format
Mono 8, Mono 10, or Mono 12 bit depth to Camera Link.
Test Image Selector
Select an internal test image:
Off
Ramp
A5
Each Tap Fixed
All 1365
All 1
Set Baud Rate
The baud rate sets the speed (in bits per second—bps) of the serial communication port and is available as
part of the Serial Port Control parameters.
Serial Port Control
Action
Parameter
Options
Control the baud rate used by the
camera‘s serial port
Baud Rate
9600 (factory default)
19200
57600
115200
230400*
460800*
921600*
Note: During connection CamExpert
automatically sets the camera to
maximum allowable baud.
*A Px8 or equivalent frame grabber is
required in order to achieve these baud