User`s manual

Piranha4 4K and 2K Dual Line Monochrome CMOS Camera User's Manual 31
Teledyne DALSA 03-032-20176-02
Check Camera and Sensor Information
Camera and sensor information can be retrieved via a controlling applicationfor example, the
CamExpert GUI shown in the following examples. Parameters such as camera model, firmware version,
sensor characteristics, etc. are read to uniquely identify the connected device.
The camera information parameters are grouped together as members of the Camera Information set.
Figure 15. CamExpert’s Camera Information Window
Verify Temperature and Voltage
To determine the voltage and temperature at the camera, use the Refresh Voltage and Refresh
Temperature features found in the Camera Information set.
The temperature returned is the internal temperature in degrees Celsius. For proper operation this value
should not exceed 80 °C. If the camera exceeds the designated temperature it will stop imaging and the
LED will turn red. Once you have diagnosed and remedied the issue use the reset camera function.