User`s manual
Piranha4 2K and 4K Color Camera User's Manual 83
Teledyne DALSA 03-032-20180-02
On
On
FPN and flat field coefficients
enabled.
DFNC
Initialize
Initialize
Reset all FPN to 0 and all flat
field coefficients to 1.
ScanDirectionControlled
ScanDirectionControlled
Different user set loaded
depending on direction.
Select flatfield
Correction Scan
Direction Reverse Set
flatfieldScanDirectionReverseSet
When flatfieldCorrectionMode is
set to ScanDirectionControlled
this feature selects the UserSEt (1
to 8) which will be used for the
reverse scan direction.
1.00
Beginner
DFNC
Calibration Algorithm
flatfieldCorrectionAlgorithm
Selection between two different
flat field algorithms.
1.00
Beginner
DFNC
Basic
Basic
Direct calculation of coefficients
based on average line values and
target. First each color is flat
fielded to its peak value and
then the color gains are used to
achieve the target.
LowPass
LowPass
A low pass filter is first applied
to the average line values before
calculating the coefficients. Use
this algorithm if the calibration
target is not uniformly white or
it is not possible to defocus the
image. Because of the low pass
filter this algorithm is not able to
correct pixel-to-pixel variations
and so it is preferable to use the
―Basic‖ algorithm.
Calibration Target
flatfieldCalibrationTarget
Set a value between 0 and 255 to
which the flat field algorithm
will taget the image to.
1.00
Beginner
DFNC
Calibration Sample Size
Lines_2048
Lines_4096
flatfieldCalibrationSampleSize
Lines_2048
Lines_4096
Sets the number of lines to be
averaged during a flat field
calibration
1.00
Beginner
DFNC
ROI Offset X
flatfieldCalibrationROIOffsetX
Set the starting point of a region
of interest where a flat field
calibration will be performed
1.00
Beginner
DFNC
ROI Width
flatfieldCalibrationROIWidth
Sets the width of the region on
interest where a flat field
calibration will be performed
1.00
Beginner
DFNC
Calibrate FPN
flatfieldCalibrationFPN
Initiates the FPN calibration
process
1.00
Beginner
DFNC
Calibrate PRNU
flatfieldCalibrationPRNU
Initiates the PRNU or Flatfield
process
1.00
Beginner
DFNC