User`s manual
58 Piranha HS 4x User’s Manual
03-32-10040-03 PRELIMINARY DALSA Corp.
Command
Function
Syntax Parameters Command and Parameter
Description
write pixel coeffs
wpc
Write all current pixel coefficients to
EEPROM.
write user
settings
wus
Writes all of the user settings to the
EEPROM.
B2 Error Handling
The following tables list the codes for errors, informal messages, and monitoring task
messages.
Error Codes
Code Description Suggested Cause
0 Command executed successfully Command executed without major error
detected
1 Internal camera error (PIXEL
INDEX)
Internal software error trap
2 Internal camera error (RESULT
CODE)
Internal software error trap
3 Invalid command Command not recognized
4 Command parameters incorrect or
out of range
Command parameters are invalid or out of
range
5 Command not available in current
mode
ssf is unavailable in mode 3
8 Command not available in VIDEO
TEST mode
sao, sg
10 Camera memory check failure Memory test of external RAM failed
11 Unable to configure DSP DSP (FPGA) configuration failure
12 DSP configuration reset failure DSP (FPGA) could not be placed in
configuration mode
13 Get line process command timed
out, check for the presence of
external signals
gl,gla,cao,cag timed out. Current exposure
mode requires external SYNC, however
SYNC signal not present
14 DSP echo test error DISC bus communication test failure
15 Invalid sensor configuration
(DSP)
Invalid sensor configuration read from
DSP (FPGA)
16 Invalid sensor configuration
(ADC)
Invalid sensor configuration encoding on
the board
17 Sensor configuration mismatch Sensor configuration read from DSP is
different than one encoded on the board
18 One (or more) of the supply
voltages is out of specification
vv command result
19 The camera's temperature is
outside the specified operating
range
vt command result
21 Analog offset calibration failure Analog offset calibration failure (could not
tune the analog offset to obtain targeted