User`s manual

Piranha HS 4x User’s Manual 57
DALSA Corp. PRELIMINARY 03-32-10040-03
Command
Function
Syntax Parameters Command and Parameter
Description
set lower
threshold
slt i
Sets the lower threshold value that is
checked for and reported in the end-of-line
statistic.
i= Lower threshold value with a range
from
0 to 255 DN for 8 bit data modes, and
0 to 1023 DN for 10 bit data modes.
set prnu coeff
spc i i
Set the PRNU coefficient. The first
parameter is the pixel number within the
range 1 to 2048. The second parameter
is a specified value within the range 0 to
511 DN.
set subtract
background
ssb t i
Subtracts the input value from the output
signal.
t
= Tap value. 0 for all taps or 1-4 for
individual tap selection.
i= The second parameter is the subtracted
value in a range from
0 to 511.
set sync
frequency
ssf f
Sets the line rate, in exposure mode 7, to a
value from 1000 to 51540 Hz when
operating in sbv 1 or 1000 to 48850 Hz
when operating in sbv 2.
set system gain
ssg t i
Sets the digital gain.
t= Tap value. 0 for all taps or 1-4 for
individual tap selection.
i= Gain value in a range from 0 to 511.
stage select
stg i
Sets the number of TDI stages to use.
i = 16, 24, 32, 48, or 64. Factory setting is
64.
set upper
threshold
sut i
Sets the upper threshold value that is
checked for and reported in the end-of-line
statistic.
i= 0 to 255 DN in 8 bit mode, or 0 to 1023
DN in 10 bit mode.
set video mode
svm i
Sets the video mode, where i is:
0= Video mode
1= Test pattern
verify
temperature
vt
Checks the internal temperature of the
camera.
verify voltage
vv
Checks the camera voltages and returns
OK or error message.
warning enabled
disabled
wed [i i]
Reads or enables/disables the status of all
defined monitoring tasks.
[i]= Selects a specific monitoring task.
[i]= Enables or disables the selected task.
For more information, see section 3.13
Monitoring Tasks.