User`s manual
56 Piranha HS 4x User’s Manual
03-32-10040-03 PRELIMINARY DALSA Corp.
Command
Function
Syntax Parameters Command and Parameter
Description
set analog offset
sao t i
Sets the analog offset.
t = Tap value. 0 for all taps or 1-4 for
individual tap selection.
i= Controls the digital analog converter
(DAC) in a range from 0 to 1023, that sets
analog offset. Offset increases with higher
values.
set binning
horizontal
sbh i
Sets the horizontal binning factor.
i = 1 (factory setting) or 2
set binning
vertical
sbv i
Sets the vertical binning factor.
i = 1 (factory setting) or 2
set baud rate
sbr i
Sets the speed (baud rate) of the camera
serial communication port.
i= 9600, 19200, 57600, and 115200.
Power up baud is always 9600.
set data mode
sdm i
Sets the data mode of the camera where i
is:
0 = 8 bit, A/B/C/D ports, single processor
1 = 10 bit, A/B/C and D/E/F ports, single
processor
2 = 8 bit, A/B, time multiplexed
3 = 10 bit A/B/C, time multiplexed
set digital offset
sdo t i
Subtracts the input value from the video
signal prior to the PRNU correction. The
first parameter is the tap selection
1 to 4, 0
for all taps. The second parameter is the
offset in a range from
0 to 511.
set exposure
mode
sem i
Sets the exposure mode to use where i is:
3 = External SYNC, maximum exposure
time (no shuttering).
7 = Internal programmable SYNC,
maximum exposure time. Factory setting.
Set FPN
coefficient
sfc i i
Sets an individual pixel’s coefficient value.
i = The pixel to set in range from 1 to
2048.
i = The coefficient value to set in a range
from
0 to 63.
set gain
sg t f
Sets the analog gain.
t= Tap value. 0 for all taps or 1-4 for
individual tap selection.
f= Analog gain setting in a range from –
10 to 10dB.