User`s manual

Piranha HS 4x User’s Manual 13
DALSA Corp. PRELIMINARY 03-32-10040-03
Camera Link Cable
Medium Configuration Base Configuration
Up to an additional 2 Channel Link Chips One Channel Link Chip + Camera
Control + Serial Communication
Camera
Connector
Right
AngleFrame
Grabber
Channel
Link Signal
Cable
Name
Camera
Connector
Right Angle
Frame
Grabber
Channel
Link Signal
4 23 Y2- PAIR3- 4 23 X2-
17 10 Y2+ PAIR3+ 17 10 X2+
5 22 Yclk- PAIR4- 5 22 Xclk-
18 9 Yclk+ PAIR4+ 18 9 Xclk+
6 21 Y3- PAIR5- 6 21 X3-
19 8 Y3+ PAIR5+ 19 8 X3+
7 20 100 ohm PAIR6+ 7 20 SerTC+
20 7 terminated PAIR6- 20 7 SerTC-
8 19 Z0- PAIR7- 8 19 SerTFG-
21 6 Z0+ PAIR7+ 21 6 SerTFG+
9 18 Z1- PAIR8- 9 18 CC1-
22 5 Z1+ PAIR8+ 22 5 CC1+
10 17 Z2- PAIR9+ 10 17 CC2+
23 4 Z2+ PAIR9- 23 4 CC2-
11 16 Zclk- PAIR10- 11 16 CC3-
24 3 Zclk+ PAIR10+ 24 3 CC3+
12 15 Z3- PAIR11+ 12 15 CC4+
25 2 Z3+ PAIR11- 25 2 CC4-
13 13 inner shield Inner Shield
13 13 inner shield
26 26 inner shield Inner Shield
26 26 inner shield
*Exterior Overshield is connected to the shells of the connectors on both ends.
**3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.
Unused pairs should be terminated in 100 ohms at both ends of the cable.
Table 4: DALSA Camera Control Configuration
Camera Link Signal DALSA Configuration
CC1 EXSYNC
CC2 Spare
CC3 Spare
CC4 Spare
Figure 5: Hirose 6-pin Circular Male Power Connector
Hirose 6-pin Circular Male
5
4
6
2
3
1
Mating Part: HIROSE
HR10A-7P-6
S
i
See Appendix A on page
47 for more information
on the DALSA Camera
Link configuration table,
and refer to the DALSA
Vision for Machines Web
site, vfm.dalsa.com
, for the
official Camera Link
documents.