User`s manual
Piranha HN RoHS User Manual
03-032-20135-00 Teledyne DALSA
18
4. Software Interface: How to
Control the Camera
All Piranha HN-xx camera features can be controlled through the serial interface. The camera can also be
used without the serial interface after it has been set up correctly. Functions available include:
• Controlling basic camera functions such as gain and sync signal source.
• Flat field correction.
• Mirroring and readout control.
• Generating a test pattern for debugging.
The serial interface uses a simple ASCII-based protocol and the PC does not require any custom software.
Note: This command set has changes from previous Teledyne DALSA cameras. Do not assume that the
Piranha HN commands perform similarly to older cameras.
Serial Protocol Defaults
• 8 data bits
• 1 stop bit
• No parity
• No flow control
• 115,200 kbps (fixed)
• Camera does not echo characters
Command Format
When entering commands, remember that:
• A carriage return <CR> ends each command.
• A space or multiple space characters separate parameters. Tabs or commas are invalid parameter
separators.
• Upper and lowercase characters are accepted
• The backspace key is supported
• The camera will answer each command with either <CR><LF> “OK >" or <CR><LF>"Error xx: Error
Message >" or <CR><LF>“Warning xx: Warning Message >”. The ">" is used exclusively as the last
character sent by the camera.
The following parameter conventions are used in the manual:
•
i = integer value
•
f = real number
•
m = member of a set
•
s = string
•
t = tap id
•
x = pixel column number