User`s manual

Piranha HN RoHS User Manual
Teledyne DALSA 03-032-20135-00
11
Figure 3: Piranha HN-xx Input and Output Connectors
WARNING: It is extremely important that you apply the appropriate voltages to your
camera. Incorrect voltages will damage the camera. See
Power Connector for more
details.
LED Status Indicator
The camera is equipped with a red/green LED used to display the operational status of the camera. The
table below summarizes the operating states of the camera and the corresponding LED states.
When more than one condition is active, the LED indicates the condition with the highest priority. Error
and warning states are accompanied by corresponding messages further describing the current camera
status.
Table 2: Diagnostic LED
Priority Color of Status LED Meaning
1 Flashing Red Fatal Error. Camera temperature is too high and camera thermal
shutdown has occurred or a power on failure has been detected.
2 Solid Red Warning. Loss of functionality.
3 Flashing Green Camera initialization or executing a long command (e.g., flat field
correction command
ccf
)
4 Solid Green Camera is operational and functioning correctly.
Camera Link (Base, Medium or Full Configuration)
Camera Link (Medium or Full Configuration)
Diagnostic LED
+12VDC to +15VDC and Ground
!