User`s manual

PC2-CamLink User's Manual Part I: PC2-CamLink Board 27
PRIN Pulse Generator
Ext. Trigger
PRIN
Offset
Active
Time
Figure 4: PRIN Pulse Generator
The PRIN signal can be selected as an output on any of the four camera control lines on the Camera
Link™ connector.
Note: The PRIN pulse is always fired from the selected trigger event.
Sapera Parameters for PRIN:
Refer to Time Integration method in the Sapera Acquisition Parameters Reference
manual. PRIN is typically designated by pulse #0 in the various time integration
methods.
CORACQ_PRM_TIME_INTEGRATE_METHOD: Method to use for time integration
CORACQ_PRM_TIME_INTEGRATE_PULSE0_DELAY: Pulse offset from trigger
event
CORACQ_PRM_TIME_INTEGRATE_PULSE0_DURATION: Size of pulse
CORACQ_PRM_TIME_INTEGRATE_PULSE0_POLARITY =
{CORACQ_VAL_ACTIVE_LOW, CORACQ_VAL_ACTIVE_HIGH}
Note: Sapera also support Camera Reset methods and Camera Trigger methods. Refer to
the Sapera Acquisition Parameters Reference manual for more information.
In CamExpert, these parameters are found under the ‘Advanced Control Parameters’
tab. Select one of the camera control methods (camera reset, camera trigger, or time
integration).
IFC
IFC Parameters for PRIN:
CL2_PRI_ENABLE = {IFC_DISABLE, IFC_ENABLE}
CL2_PRI_POLARITY = {IFC_ACTIVE_LOW, IFC_ACTIVE_HIGH}
CL2_PRI_OFFSET_TIME: Pulse offset from trigger event
CL2_PRI_ACTIVE_TIME: Size of pulse
CL2_ COMBINE_EXSYNC_PRI = {IFC_DISABLE, IFC_ENABLE}