User`s manual

PC2-CamLink User's Manual Part III: IFC 109
LNK_TTL_TRIG
LNK_OPTO_COUPLED_TRIG
CL2_OPTO_FRAME_TRIG1
CL2_OPTO_FRAME_TRIG2
CL2_LVDS_FRAME_TRIG1
CL2_LVDS_FRAME_TRIG2
CL2_FREQ_FRAME_TRIG
Use
LNK_EXT_SYNC_PERIOD_TIME
CL2_FRAME_TRIG_FREQ Float range parameter,min:0.1,
max:10000, step size:0.1 Hz
LINE TRIGGER
GROUP
Only available if P_FEN_ENABLE is
disabled
Implicitly activated by EXSYNC and
PRI on PC-CamLink
CL2_LINE_TRIG_ENABLE IFC_DISABLE
IFC_ENABLE
CL2_LINE_TRIG_SRC CL2_TIMER_LINE_TRIG
CL2_SHAFT_LINE_TRIG
Use
LNK_EXT_SYNC_PERIOD_TIME
CL2_LINE_TRIG_CYCLE_TIME Integer range parameter, min:1,
max:65535, step size:1 μs
Use LNK_TMODE_DISABLE P_VFRAME_TRIGGER_ENABLE IFC_DISABLE
IFC_ENABLE
P_TRIGGER_POLARITY IFC_FALLING_EDGE
IFC_RISING_EDGE
P_VFRAME_TRIGGER_POLARITY IFC_FALLING_EDGE
IFC_RISING_EDGE
IFC_POL_ACTIVE_LOW
IFC_POL_ACTIVE_HIGH
LNK_TRIG_GLITCH_DETECTOR IFC_DISABLE
IFC_ENABLE
P_VFRAME_TRIGGER_DEBOUNCE Integer range parameter, min:0,
max:255, step size:1μs
P_TRIGGER_SRC
+
LNK_TRIG_START_EVENT
+
LNK_TRIG_STOP_EVENT
LNK_DIFFERENTIAL_TRIG
LNK_TTL_TRIG
LNK_OPTO_COUPLED_TRIG
LNK_TMODE_DISABLE
LNK_TMODE_HWTRIG0_ASSERT
LNK_TMODE_HWTRIG0_DEASSE
RT
LNK_TMODE_HWTRIG1_ASSERT
LNK_TMODE_HWTRIG1_DEASSE
RT
LNK_TMODE_SWTRIG0
LNK_TMODE_SWTRIG1
LNK_TMODE_DISABLE
LNK_TMODE_HWTRIG0_ASSERT
LNK_TMODE_HWTRIG0_DEASSE
RT
LNK_TMODE_HWTRIG1_ASSERT
LNK_TMODE_HWTRIG1_DEASSE
RT
LNK_TMODE_SWTRIG0
LNK_TMODE_SWTRIG1
CL2_VFRAME_TRIG_SOURCE CL2_SOFT_VFRAME_TRIG
CL2_OPTO_VFRAME_TRIG
1
CL2_OPTO_VFRAME_STAR
TTRIG1_STOPTRIG2
CL2_LVDS_VFRAME_TRIG
1
CL2_LVDS_VFRAME_STAR
TTRIG1_STOPTRIG2
LNK_TRIG_DIVIDE_FACTOR Range: 1 to 256, step size 1 CL2_LINE_TRIG_DROP_COUNT Integer range parameter, min:0,
max:255, step size:1 trigger
No equivalent on PC-CamLink CL2_LINE_TRIG_NUM_PHASES Integer range parameter: min:1,
max:2, step size:1
No equivalent on PC-CamLink CL2_LINE_TRIG_DEBOUNCE Integer range parameter: min:0,
max:255, step size:1μs