User`s manual
Linea 2K, 4K, 8K and 16K Camera User's Manual  PRELIMINARY    9 
Teledyne DALSA    03-032-20206-01 
Operating Temp 
0 °C to 65 °C, front plate temperature 
Optical Interface 
Sensor to Camera Front Distance 
  12 mm 
Sensor Alignment (aligned to sides of camera) 
 y (parallelism) 
x  
y 
z 
 z 
0.08° or 100 µm 
± 300 µm 
± 300 µm 
± 300 µm 
± 0.3° 
Compliance 
Regulatory Compliance 
CE, FCC, and RoHS; GenICam 
Operating 
Ranges 
Performance 
Notes 
2K 
4K 
8K 
16K 
Dynamic 
Range 
dB 
> 60 
> 60 
> 60 
> 60 
Random 
Noise 
DN* rms 
< 3.75 
< 3.75 
< 3.75 
< 3.75 
FFC enabled 
Broadband 
Responsivity 
DN / (nJ / 
cm
2
) 
320 
320 
320 
80 
Gain 
Nominal 
range 
1x to 10x 
1x to 10x 
1x to 10x 
1x to 10x 
DC Offset 
DN 
7 
7 
7 
7 
FFC enabled 
PRNU 
@ 50% Sat 
< 1.5% 
< 1.5% 
< 1.5% 
< 1.5% 
FPN 
DN 
< 7 
< 7 
< 7 
< 7 
SEE 
nJ / cm
2
12.5 
12.5 
12.5 
46.9 
NEE 
pJ / cm
2
11.7 
11.7 
11.7 
51 
Antiblooming 
(x Saturation) 
> 100 
> 100 
> 100 
> 100 
Integral non-
linearity 
DN 
1.5 %  
1.5 %  
1.5 %  
1.5 %  
*DN = digital number 
Test Conditions: 
  Values measured using 12-bit @ 1x gain. 
  10 kHz line rate. 
  Light source: broadband, quartz halogen, 3250 K with 700 nm IR cut-off filter. 
  Front plate temperature: 45º C. 