User`s manual
Linea 2K, 4K, 8K and 16K Camera User's Manual  PRELIMINARY    73 
Teledyne DALSA    03-032-20206-01 
Full Name 
Help 
Mnemonic 
H 
Argument(s) 
Description 
Display list of three letter commands (2K help screen shown) 
Notes 
USER>h 
LA (03-081-20315-00 ): Command Line Interpreter Jan 15 2014, 
17:46:53 
ccf - Calibrate User FPN <2048|4096> 
clm - Camera Link Mode <0:Base 1:Med 2:Full> 
cls - Camera Link Speed <0 - 77MHz, 1 - 49MHz> 
cpa - Calibrate Flatfield <0:basic 1:filter><2048|4096><DN 
target> 
dek - disable ESC key <0/1>  
ffm - Flat Field Mode <0:Off 1:On 2:Initialiaze> 
gcp - Display Camera Configuration 
get - Get value '<string> 
h  - Help 
? -  help '<string>  
lpc - Load Pixel Coefficients <set 0-8> 
rc  - Reset Camera 
roi - Set Flatfield ROI <1st pixel> <last pixel> 
rpc - Reset Flatfield Coefficients 
sac - Set AOI Count <value 1-4> 
sad - Set AOI Selector, Offset and Width <selector 1-AOI Count> 
<1st pixel> <width >= 40> 
sam - Set AOI Mode <1-enable, 0-disable> 
sbh - Horizontal Binning <1|2> 
sbr - Set Baud Rate <9600|57600|115200|230400|460800> 
sbv - Vertical Binning <1|2> 
sem - Exposure Mode <0:Int 1:Ext> 
set - Exposure Time <ns> 
smm - Mirroring <0:Off 1:On> 
spf - Pixel Format <0:8 bits 1:10 bits 2:12 bits> 
ssb - Offset <DN> 
ssf - Internal Line Rate <Hz> 
ssg - Gain <0:System> f<gain> 
stm - External Trigger <0:Off 1:On> 
sui - Set User ID 
svm - Test Pattern <0-1> 
usd - Default User Set <0-8> 
usl - Load User Set <0-8> 
uss - Save User Set <1-8> 
vt  - Temperature 
vv  - Input Voltage 