User`s manual
32  PRELIMINARY  Linea 2K, 4K, 8K and 16K Camera User's Manual 
03-032-20206-01    Teledyne DALSA 
The camera can grab images in one of three ways. You determine the three imaging modes using a 
combination of the Exposure Mode parameters (including I/O parameters), Exposure Time and Line Rate 
parameters. 
Description 
Line Rate 
Exposure Time 
Trigger Source 
(Sync) 
Internal line rate and exposure time 
Internal, programmable 
Internal programmable 
Internal 
External line rate and exposure time 
Controlled by EXSYNC 
pulse 
External (EXSYNC) 
External 
EXSYNC pulse controlling the line 
rate. Programmed exposure time. 
Controlled by EXSYNC 
pulse 
Internal programmable 
External 
Figure 13. Exposure controls 
The parameters used to select the imaging modes—trigger sources (sync), exposure time, and line rate—
are grouped together as the Camera Controls. 
Camera Controls 
Parameter 
Description 
Line Rate (in Hz) 
Camera line rate in Hz. Only available when the start line trigger parameter 
is disabled (Trigger Mode off). 
Exposure Mode 
Set the operation mode for the camera‘s exposure. 
Trigger Width or Timed. Trigger Width is only available when Trigger 
Mode is enabled. 
Trigger Width 
Uses the width of the current line trigger signal pulse to control the 
exposure duration. 
Timed 
The exposure duration time is set using the Exposure Time feature and the 
exposure starts with the Line Start event. 
Exposure Time 
Sets the exposure time (in microseconds). Exposure Mode feature must be 
set to Timed 
Exposure Modes in Detail 
1. Internally Programmable Line rate and Internally Programmable Exposure Time (Default)  
Line rate is the dominant factor when adjusting the line rate or exposure time. When setting the line rate, 
exposure time will decrease, if necessary, to accommodate the new line rate. When adjusting the 
exposure time the range is limited by the line rate. 
Note: The camera will not set line periods shorter than the readout period. 
GenICam parameters to set: 
I / O Controls > Trigger Mode > Off 
2. External Line Rate and External Exposure Time (Trigger Width)  
In this mode, EXSYNC sets both the line period and the exposure time. The rising edge of EXSYNC marks 
the beginning of the exposure and the falling edge initiates readout. Note: 