User`s manual
Linea 2K, 4K, 8K and 16K Camera User's Manual  PRELIMINARY    29 
Teledyne DALSA    03-032-20206-01 
Verify Temperature and Voltage 
To determine the voltage and temperature at the camera, use the Refresh Voltage and Refresh 
Temperature features found in the Camera Information set. 
The temperature returned is the internal temperature in degrees Celsius. For proper operation this value 
should not exceed 80 °C. If the camera exceeds the designated temperature it will stop imaging and the 
LED will turn red. Once you have diagnosed and remedied the issue use the reset camera function. 
Note: The voltage displayed is the camera‘s input voltage. The voltage measurement feature of the camera 
provides results within 1% of the actual voltage. The measurement can be used to set the applied voltage 
to the camera. 
Saving and Restoring Camera Settings 
The parameters used to select, load and save user sets are grouped together under the Camera 
Information set of features. There are 8 user sets available and one factory set. 
Camera Information 
Parameter 
Choices 
User Set Default Selector 
Select the camera parameters to load when the camera is reset or 
powered up as the Factory set, or as User Set 1 to 8. 
Selecting the set from the list automatically saves it as the default 
set. 
User Set Selector 
Select the Factory or User set to Save or Load. 
-Factory Set 
-User Set 1 to 8. 
User Set Load 
Load the set specified by User Set Selector to the camera and make 
it the active / current set. 
User Set Save 
Save the current set as selected user set. 
Description of the Camera Settings 
The camera operates in one of four settings: 
1.  Current operation with active settings. 
2.  User setting.  
3.  Factory setting (read-only). 
4.  Default setting. 
The settings active during the current operation can be saved (thereby becoming the user setting) using 
the User Set Save parameter. A previously saved user setting (User Set 1 to 8) or the factory settings can 
be restored using the User Set Selector and User Set Load parameters. 
Either the Factory or one of the User settings can be saved as the Default Setting by selecting the set in the 
User Set Default Selector. The chosen set automatically saves as the default setting and is the set loaded 
when the camera is reset or powered up. 