Linea 2K, 4K, 8K and 16K Camera User's Manual  PRELIMINARY    21 
Teledyne DALSA    03-032-20206-01 
Deca 
Configuration 
T0 
Pixel Format 
Port A 
LSB… 
Bit 7 
Port B 
LSB… 
Bit 8 
Port C 
LSB… 
Bit 8 
Port D 
LSB… 
Bit 8 
Port E 
LSB… 
Bit 8 
Port F 
LSB… 
Bit 8 
Port G 
LSB… 
Bit 8 
Port H 
LSB… 
Bit 8 
Port I 
LSB…Bit 8 
Port K 
LSB…B
it 8 
Mono 8 
Tap 1 
LSB… 
Bit 7 
Pixels (1, 
11, 21, ... 
4081, 
4091) 
Tap 2 
LSB… 
Bit 7 
Pixels 
(2, 12, 
22, ... 
4082, 
4092) 
Tap 3 
LSB… 
Bit 7 
Pixels 
(3, 13, 
23, ... 
4083, 
4093) 
Tap 4 
LSB… 
Bit 7 
Pixels 
(4, 14, 
24, ... 
4084, 
4094) 
Tap 5 
LSB… 
Bit 7 
Pixels 
(5, 15, 
25, ... 
4085, 
4095) 
Tap 6 
LSB… 
Bit 7 
Pixels 
(6, 16, 
26, ... 
4086, 
4096) 
Tap 7 
LSB…B
it 7 
Pixels 
(7, 17, 
27, ... 
4087) 
Tap 8 
LSB… 
Bit 7 
Pixels 
(8, 18, 
28, ... 
4088) 
Tap 9 
LSB… 
Bit 7 
Pixels (9, 
19, 29, ... 
4089) 
Tap 10 
LSB… 
Bit 7 
Pixels 
(10, 20, 
30, ... 
4090) 
Table 5: Camera Link Bit Definitions 
Signal 
Configuration 
CC1 
EXSYNC 
CC2 
Spare 
CC3 
Spare 
CC4 
Spare 
Table 6: Camera Control Configuration 
For additional Camera Link documentation refer to the Teledyne DALSA Web site‘s Knowledge Center 
application notes. 
Camera Link Drive Capability 
The camera link cable drive capability on the cameras can reach up to 10 meters. This capability has been 
tested using a number of frame grabbers (listed in the table below) and was tested using standard 
Camera Link cables. The cable length drive achieved on the various frame grabbers is as follows: 
Cable Length 
Frame Grabber (Manufacturer / Part Number) 
7 meter 
TeledyneDALSA Xcelera-CL PX4 / OR-X4C0-XPF00 
10 meter 
TeledyneDALSA Xtium-CL PX4 / OR-Y4C0-XPX00 
Table 7: Cable Length and Frame Grabber Pairings 
Input Signals, Camera Link 
The camera accepts control inputs through the Camera Link SDR26F connector. The camera ships in 
internal sync, and internally programmed integration. 
EXSYNC (Line Readout Trigger) 
 Line rate can be set internally using the GenICam features. The external control signal EXSYNC is 
optional and enabled through the user interface. This camera uses the falling edge of EXSYNC to trigger 
pixel readout. 