User`s manual

78 Operational Reference Genie HM-HC Series-GigE Vision Camera
OutputSelectorOutput_1 RW Always ENUM Open = 0
Close = 1
Strobe On: Start of Exposure = 2
Pulse On: Valid Trigger = 4
Pulse On: Invalid Trigger = 5
Pulse On: Start of Readout = 6
Pulse On: End of Readout = 7
Pulse On: End of Acquisition = 8
Pulse On: Input 1 = 9
Pulse On: Input 2 = 10
OutputSelectorOutput_2 RW Always ENUM Open = 0
Close = 1
Pulse On: End of Exposure = 3
Pulse On: Valid Trigger = 4
Pulse On: Invalid Trigger = 5
Pulse On: Start of Readout = 6
Pulse On: End of Readout = 7
Pulse On: End of Acquisition = 8
Pulse On: Input 1 = 9
Pulse On: Input 2 = 10
PolarityInput_1 RW Always ENUM Active High = 0
Active Low = 1
PolarityInput_2 RW Always ENUM Active High = 0
Active Low = 1
PolarityOutput_1 RW Always ENUM Active Close = 0
Active Open = 1
PolarityOutput_2 RW Always ENUM Active Close = 0
Active Open = 1
PixelFormat RW N.conn ENUM 8-bit = 17301505 (0x1080001)
10-bit = 17825795 (0x1100003)
Bayer Raw8 = 17301513
Bayer Raw10 = 17825805
Power-upConfig RW N.acq ENUM Factory Default = 0
Camera Configuration 1 = 1
TimestampResetSource RW Always ENUM Off = 0
Input 1 = 1
Input 2 = 2
TimestampCounter RW Always ENUM Internal Clock (1µs resolution) = 0
Input 1 = 1
Input 2 = 2
End of Readout = 3
SaveCameraConfigurationSelector RW N.conn ENUM Camera Configuration 1 = 1
LoadCameraConfigurationSelector RW N.conn ENUM Factory Default = 0
Camera Configuration 1 = 1
IPConfigurationMode RW N.acq ENUM DHCP/LLA mode = 0
Persistent IP mode = 1
NetworkConfigurationMode RW N.conn ENUM Automatic = 0
Manual = 1