User`s manual
78  Operational Reference  Genie HM-HC Series-GigE Vision Camera 
OutputSelectorOutput_1  RW  Always  ENUM  Open = 0 
Close = 1 
Strobe On: Start of Exposure = 2 
Pulse On: Valid Trigger = 4 
Pulse On: Invalid Trigger = 5 
Pulse On: Start of Readout = 6 
Pulse On: End of Readout = 7 
Pulse On: End of Acquisition = 8 
Pulse On: Input 1 = 9 
Pulse On: Input 2 = 10 
OutputSelectorOutput_2  RW  Always  ENUM  Open = 0 
Close = 1 
Pulse On: End of Exposure = 3 
Pulse On: Valid Trigger = 4 
Pulse On: Invalid Trigger = 5 
Pulse On: Start of Readout = 6 
Pulse On: End of Readout = 7 
Pulse On: End of Acquisition = 8 
Pulse On: Input 1 = 9 
Pulse On: Input 2 = 10 
PolarityInput_1  RW  Always  ENUM  Active High = 0 
Active Low = 1 
PolarityInput_2  RW  Always  ENUM  Active High = 0 
Active Low = 1 
PolarityOutput_1  RW  Always  ENUM  Active Close = 0 
Active Open = 1 
PolarityOutput_2  RW  Always  ENUM  Active Close = 0 
Active Open = 1 
PixelFormat  RW  N.conn  ENUM  8-bit = 17301505 (0x1080001) 
10-bit = 17825795 (0x1100003) 
Bayer Raw8 = 17301513 
Bayer Raw10 = 17825805 
Power-upConfig  RW  N.acq  ENUM  Factory Default = 0 
Camera Configuration 1 = 1 
TimestampResetSource  RW  Always  ENUM  Off = 0 
Input 1 = 1 
Input 2 = 2 
TimestampCounter  RW  Always  ENUM  Internal Clock (1µs resolution) = 0 
Input 1 = 1 
Input 2 = 2 
End of Readout = 3 
SaveCameraConfigurationSelector  RW  N.conn  ENUM  Camera Configuration 1 = 1 
LoadCameraConfigurationSelector RW  N.conn  ENUM  Factory Default = 0 
Camera Configuration 1 = 1 
IPConfigurationMode RW N.acq  ENUM  DHCP/LLA mode = 0 
Persistent IP mode = 1 
NetworkConfigurationMode  RW  N.conn  ENUM  Automatic = 0 
Manual = 1 