User`s manual
56  Operational Reference  Genie HM-HC Series-GigE Vision Camera 
Strobe and General Outputs 
Genie provides two sets of opto-coupled outputs (see "External Outputs" on page 111). These can be used as a 
strobe signal to control lighting or to generate programmable pulses when specific events are generated by the 
camera. They can also be set to a static state (close or open) by the application. 
See "12-Pin Hirose Connector Signal Details" on page 108 for connect
or pinout and electrical information. 
General Outputs: Settings via CamExpert 
The Output Settings dialog box allows you to configure the event mode for both output 1 and output 2. Each 
output can be set independently to one of the available event modes. A typical usage of output is to control a strobe 
light in relation to the camera exposure. Select the output to configure by clicking on the Output 1 or Output 2 
buttons located at the top of the dialog box. Use the Event mode drop-down list box to select the required event 
mode. 
The following output signal events are available: 
  Open (default) 
  Close 
  Strobe On: Start of Exposure (used for strobe pulse) 
  Pulse On: Valid Trigger 
  Pulse On: Invalid Trigger 
  Pulse On: Start of Readout 
  Pulse On: End of Readout 
  Pulse On: End of Acquisition 
  Pulse On: Input 1 
  Pulse On: Input 2 