Genie HM-HC Series-GigE Vision Camera Operational Reference 35
Power-up Parameter List
The user-defined Camera Configuration saves in camera memory features that can be configured by the user. The
following table lists most of these parameters.
Parameter Description
ROI Region of interest used to crop the image.
Pixel Format Defines the pixel format.
Frame Rate Defines the frame rate for free run mode. (see note below)
Exposure Control mode Defines the exposure mode (Programmable or Pulse Controlled)
Exposure duration Defines the exposure duration for Programmable mode. (see note below)
Exposure synchronization Synchronous or Reset synchronization mode.
Gain Defines the sensor analog Gain factor, initially set to 0.0 dB.
Black Level Defines the sensor analog Black level factor, initially set to 0.
Flip Horizontal flip: Off or On (HM models only)
Image source Defines the image source as the sensor or one of the stored image patterns.
Trigger enable Free-running or triggered.
Trigger source Selects the trigger input (input pin or software).
Trigger delay Defines the delay from input trigger to exposure start.
GPI settings Defines the operational mode of the general input pins.
GPO settings Defines the operational mode of the general output pins
LUT Lookup Table function On or Off plus the LUT data. (HM models only)
Flat Field Correction FFC function On or Off plus the offset/gain data. (see warning below)
Note: Maximum frame rates and exposure durations saved previously with Genie Framework 1.40 may be
slightly reduced by Framework 1.50, to improve acquisition robustness.
Warning: Non-typical or invalid Flat Field data, either from a faulty calibration setup or uploaded by the user,
may cause an error when trying to save the User Settings Power-up Parameters. Such "flawed" Flat Field data is
useable during camera operation but cannot be sufficiently compressed to be saved as a user setting.
Power-up Control via Sapera LT or GigE Vision Compliant Applications
Sapera
Genie Sapera parameters for Power-up Configuration:
Power-upConfig = {Factory Default = 0, Camera Configuration 1 = 1}
SaveCameraConfigurationSelector = {Camera Configuration 1 = 1}
SaveCameraConfiguration = Write to save selected camera configuration
LoadCameraConfigurationSelector = {Factory Default = 0, Camera Configuration 1 = 1}
LoadCameraConfiguration = Write to load selected camera configuration
In CamExpert, these parameters are available in the “Camera Information” tab, under the
“Power-up Configuration” dialog box.
See "Accessing Features with Sapera++ LT" on page 76.