User`s manual
30  Installing the Genie Camera  Genie HM-HC Series-GigE Vision Camera 
Bayer CFA Decoder 
For the HC camera models, to view the acquisition display in color set the Bayer CFA Decoder to Software from 
the CamExpert Pre-Processing menu. 
About the User-Defined Camera Name 
The Genie can be programmed with a user-defined name to aid identifying multiple cameras connected to the 
network. For instance, on an inspection system with 4 cameras, the first camera might be labeled “top view”, the 
second “left view”, the third “right view” and the last one “bottom view”. The factory default user name is set to 
match the camera serial number for quick initial identification. Note that the factory programmed Genie serial 
number and MAC address are not user changeable. 
When using CamExpert, multiple Genie cameras on the network are seen as different "Genie_M640_x" devices as 
an example. Click on a Genie device user name to select it for control by CamExpert. 
An imaging application uses any one of these attributes to identify a camera: its IP address, MAC address, serial 
number or User Name. Some important considerations are listed below. 
  Do not use the camera's IP address as identification (unless it is a persistent IP) since it can change with each 
power cycle. 
  A MAC address is unique to a single camera, therefore the control application is limited to the vision system 
with that unique camera if it uses the camera's MAC address. 
  The User Name can be freely programmed to clearly represent the camera usage. This scheme is recommended 
for an application to identify cameras. In this case, the vision system can be duplicated any number of times 
with cameras identified by their function, not their serial numbers or MAC address. 