Status LED Codes 
The camera is equipped with a LED to display the operational status of the camera. When more than one condition 
is active, the LED color indicates the condition with the highest priority (such as an acquisition in progress has more 
priority than a valid IP address assignment). The following table summarizes the LED states and corresponding 
camera status. 
LED State  Definition 
LED is off  No power to the camera 
Steady Red  Camera not initialized ** 
Slow Flashing Red  Camera initialization problem ** 
  ** Often there is no serious problem with the Genie hardware. 
Wait 2-5 minutes for the Genie to load internal default firmware, 
then follow these instructions (see Updating Genie Firmware). 
Slow Flashing Blue  Waiting for an IP address 
Fast Flashing Blue  Ethernet cable disconnected (no link) 
Steady Blue  IP address assigned; 
no application connected to the camera 
Steady Green  Application connected 
Slow Flashing Green  Triggered acquisition in progress 
Fast Flashing Green  Free-running acquisition in progress 
Once the Genie has its RJ45 connected to a network, the Status LED will turn to steady blue when the IP address is 
assigned. Only at this time will it be possible by the GigE Server or any application to communicate with the 
camera. 
Note: Even if the Genie has obtained an IP address, it might be on a different subnet than the NIC it is attached to. 
Therefore, if the Genie LED is blue but an application such as CamExpert can not see it, this indicates a network 
configuration problem. See the troubleshooting section in this manual. 
Typical LED States on Power Up 
The following LED sequence occurs when the Genie is powered up connected to a network with installed Genie 
Framework software. 
Red
power connected
Flashing Blue
waiting for IP
Blue
IP assigned
Green
application
connected