User`s manual
Genie HM-HC Series-GigE Vision Camera  Genie HM/HC Series Overview  11 
Certifications 
CE 
EN55022, class A,  Radio Disturbance Characteristics 
EN61000-4-2,    Electrostatic discharge immunity test 
EN61000-4-3,  Radiated, radio-frequency, electromagnetic field immunity test 
EN61000-4-4,    Electrical fast transient/burst immunity test 
EN61000-4-6,    Immunity to conducted disturbances, induced by radio-frequency fields 
FCC 
Part 15, class A 
see "EC & FCC Declaration of Conformity" on page 124  
RoHS 
Compliancy as per European directive 2002/95/EC 
(applies to camera part numbers CR-GENx-xxxxx) 
Vibration and Shock Certifications 
Test (while operating)  Standard  Description 
Sinusoidal vibrations with identification 
of critical frequencies 
IEC 68-2-6 (1995) 
Test Fc 
Frequency range: 10 to 2000 Hz 
Amplitude: 5 m/s
2
Sweep rate: 1 octave per minute 
Duration: 1 sweep cycle (to and fro) 
Random vibrations  MIL-STD-810E (1989) 
method 514.4 
Category 10 
Levels and frequencies: 
0.04 g
2
/Hz from 20 to 1000 Hz 
-6 dB/oct. from 1000 to 2000 Hz 
Duration: 1 hour 
Shocks  IEC 68-2-27 (1987) 
Test Ea and guide 
Shape: half-sine 
Amplitude: 75 g 
Duration: 3 ms 
Number: 3 shocks (+) and 3 shocks (-) 
Supported Industry Standards 
Genie cameras are 100% compliant with the GigE Vision 1.0 specification 
which defines the communication interface protocol used by any GigE 
Vision device. The device description and capabilities are contained in an 
XML file. For more information see: 
http://www.machinevisiononline.org/public/articles/index.cfm?cat=167 
Genie cameras implement a superset of the GenICam™ specification which 
defines device capabilities. This description takes the form of an XML 
device description file respecting the syntax defined by the GenApi module 
of the GenICam™ specification. For more information see 
www.genicam.org. 