User`s manual
Genie HM-HC Series-GigE Vision Camera  Technical Specifications  109 
Genie Signal Electrical Details 
  Power Supply (pin 2): +12V DC nominal at 0.6 Amp minimum. 
Operating tolerance: see Camera Performance Specifications 
Ov
er voltage and reverse voltage protection circuit built in. The protection circuit is reset by shutting down or 
disconnecting the power supply. 
  The 12-pin Hirose male connector shell and cable shield should connect to the supply earth ground to improve 
EMI and ESD shielding. 
External Inputs 
  Opto-coupled (2V to 12V, 2mA minimum) with internal current limit. 
  RS422 or TTL signal type (see figures below). 
  24 Volt signals supported with additional external current limiting (see figure below). 
  Used as trigger or integration control. 
  External signal polarity selected via configuration parameter. 
  User programmable debounce time from 1 to 255µs. 
  See "Input Controls via Sapera LT or GigE Vision Compliant Applications" on page 55. 
The opt
o-coupler is typically a Fairchild HMHA281 with the following characteristics. 
Input Electrical Parameter Description  Value 
Voltage threshold to turn OFF  0.8 V 
Voltage threshold to turn ON  2 V 
Minimum input current to turn ON  2 mA 
Maximum input current  50 mA 
Minimum input pulse width to turn ON  30 to 90µs typical dependent on input voltage 
Output rise time (typical)  10 µs 
Output fall time (typical)  50 µs 
Maximum input voltage  13 V 
Maximum reverse voltage  - 6 V 
Note: The minimum input pulse width to turn ON can be slightly longer depending on the actual input voltage. 