82 Appendix B: Error Handling and Command List
Syntax Command Params Description
csn
coefficient set
number
i
Selects the coefficient set to use, either:
0 = Factory calibrated set of FPN and PRNU coefficients.
These coefficients cannot be erased or modified.
1 = User calibrated set of FPN and PRNU coefficients.
These coefficients can be deleted or modified.
css
calibration
sample size
m
Sets the number of lines to sample when performing FPN
and PRNU calibration where m is 32(factory setting), 64,
128 , 256, 512, or 1024
ecg
enable color
gain
i
Enables or disables digital color gains
0 = Disabled
1 = Enabled
eoc
enable offset
correction
i
Enables or disables temperature color offset correct
0 = Disabled
1 = Enabled
gcp
get camera
parameters
Read all of the camera parameters.
gcs
get camera
serial
Read the camera serial number.
gcv
get camera
version
Read the firmware version and FPGA version.
get
get command
parameter
s
Display value of camera command s
gfc
Get FPN
Coefficient
x y x = 1-1400
y = 1-1024
gh
get help
Display the get help screen
gsf
get sync
frequency
i
Displays the frames per second. (i = 1)
h
help
Display the online help