User`s manual
Table Of Contents
- Introduction to the Falcon XDR and HG Cameras
- Camera Hardware Interface
- Serial Interface: How to Control the Camera
- Serial Protocol Defaults
- Command Format
- 3.1 Setting Baud Rate
- 3.2 Camera Serial Command Help Screen
- 3.3 Retrieving Information About the Camera
- 3.4 First Power Up Camera Settings
- 3.5 Saving and Restoring Settings
- 3.6 Camera Output Format
- 3.7 Setting Exposure Mode, Frame Rate and Exposure Time
- 3.8 Setting a Vertical Window of Interest
- 3.9 Flat Field Correction
- 3.10 Gain Adjustments
- 3.11 Generating a Test Pattern
- Optical and Mechanical Considerations
- Troubleshooting
- Appendix A: Camera Link™ Reference, Timing, and Configuration Table
- Appendix B: Error Handling and Command List
- Appendix C: EMC Declaration
- Technical Support
- Index

Appendix B: Error Handling and Command List 81
Appendix B: Error Handling and
Command List
B.1 All Available Commands
As a quick reference, the following table lists all of the commands available to the camera user. For
detailed information on using these commands, refer to
Chapter 4.
Parameter types are identified as:
t = tap id
i = integer value
f = real number
s = string
m = member of a set
Syntax Command Params Description
ccf
correction
calibrate FPN
Performs FPN calibration and eliminates FPN by
subtracting away individual pixel dark current.
clm
camera link
mode
m
Output mode to use:
2: Base configuration, 2 taps, 8 bit output
3: Base configuration, 2 taps, 10 bit output
cpa
calculate PRNU
algorithm
i i
Performs PRNU calibration according to the selected
algorithm.
The first parameter is the algorithm where i is:
2 = Calculates the PRNU coefficients using the entered
target value
PRNUCoefficient=
Target
(AVGPixelValue)‐(FPN+value)
sdo
i
i
i
This algorithm is useful for achieving uniform output
across multiple cameras.