User`s manual
Table Of Contents
- Introduction to the Falcon XDR and HG Cameras
- Camera Hardware Interface
- Serial Interface: How to Control the Camera
- Serial Protocol Defaults
- Command Format
- 3.1 Setting Baud Rate
- 3.2 Camera Serial Command Help Screen
- 3.3 Retrieving Information About the Camera
- 3.4 First Power Up Camera Settings
- 3.5 Saving and Restoring Settings
- 3.6 Camera Output Format
- 3.7 Setting Exposure Mode, Frame Rate and Exposure Time
- 3.8 Setting a Vertical Window of Interest
- 3.9 Flat Field Correction
- 3.10 Gain Adjustments
- 3.11 Generating a Test Pattern
- Optical and Mechanical Considerations
- Troubleshooting
- Appendix A: Camera Link™ Reference, Timing, and Configuration Table
- Appendix B: Error Handling and Command List
- Appendix C: EMC Declaration
- Technical Support
- Index

DALSA Falcon XDR and HG Series Camera User's Manual
54 Serial Interface: How to Control the Camera
PRNU coefficients.
0 = PRNU coefficients disabled
1 = PRNU coefficients enabled
Notes: The coefficient set that you are enabling or disabling is
determined by the csn value. Refer to the previous section for
an explanation of the csn command.
Example:
• epc 1 1
3.9.4 Selecting the Calibration Sample Size
Serial Command: css
Setting the Number of Frames to Sample
Purpose: Sets the number of frames to sample when performing
pixel coefficient calculations. Higher values cause
calibration to take longer but provide the most accurate
results.
Syntax:
• css i
Syntax Elements:
• i
Number of frames to sample. Allowable values are 32
(default), 64, 128 , 256, 512, or 1024.
Notes: To return the current setting, use the gcp command.
Example:
• css 1024
3.9.5 Performing FPN Calibration
Serial Commands: ccf , sfc
Calibrating All Camera Pixels
Purpose: Performs FPN calibration and eliminates FPN noise by
subtracting away individual pixel dark current.
Syntax:
• ccf