User`s manual

Table Of Contents
Falcon XDR and HG Series Camera User's Manual DALSA
Camera Hardware Interface 23
Base Configuration
One Channel Link Chip + Camera Control + Serial Communication
Camera Connector Frame Grabber Connector Channel Link Signal
20 7 SerTC-
8 19 SerTFG-
21 6 SerTFG+
9 18 CC1-
22 5 CC1+
10 17 CC2+
23 4 CC2-
11 16 CC3-
24 3 CC3+
12 15 CC4+
25 2 CC4-
13 13 inner shield or PoCL GND
26 26 inner shield or PoCL +12V PWR
Note: Exterior Overshield is connected to the shells of the connectors on both ends.
3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.
Unused pairs should be terminated in 100 ohms at both ends of the cable.
Inner shield is connected to signal ground inside camera.
DALSA Camera Control Configuration
Signal Configuration
CC1 EXSYNC
CC2 Reserved for future use
CC3 Reserved for future use
CC4 Reserved for future use
2.2.3 Input Signals, Camera Link
The camera accepts control inputs through the Camera Link SDR26F connector. The camera ships in
internal sync, internal programmed integration (exposure mode 2), and Camera Link mode 2.