Installation manual
Version 02  teledynedalsa.com/ipd  25 
Serial Port Connection 
The RS-232 serial port is accessible through the Lamp connector. By default, the serial 
port settings are set as follows: 
Port definition  Setting 
Baud Rate  115200 
Data Bits  8 
Parity  None 
Stop Bits  1 
Flow Control  None 
RS-232 Hardware Configuration 
These port settings can be changed through the GUI by configuring the “Serial Port 
Properties” in the Sherlock Embedded Client application. Refer to the online Help for 
details. 
BOA LAMP M12-5 Connector 
Pin  Name  Color 
2  RS232 RX  White 
3  GND  Blue 
5  RS232 TX  Yellow 
1,4  Not required 
Electrically, three (3) signals are required to make a serial port connection between 
BOA and another device as shown below. RS232 is a “point-to-point” connection, so the 
Receive and Transmit lines must be crossed in the cable. 
3
rd
 Party DSUB-9 Connector 
Pin  Name 
3  TX 
5  GND 
2  RX 
1,4,6,7,8,9  Not required 
Note: It is important to establish a common ground between BOA and the connecting 
3
rd
 party device. 