Installation manual
Version 02  teledynedalsa.com/ipd  23 
Panel Link Specifications 
The PL-100 module offers additional isolation for the BOA camera and simplifies wiring 
at the control panel. The module also provides power over Ethernet for single cable 
applications.  
I/O connections to the BOA camera should be wired to the TOP connectors on the PL-
100 (J2 and J3) directly. NOTE: Avoid reversing PWR/GND on the I/O connector. Doing 
so may make the PoE feature unusable. In this case power must always be supplied 
through the IO cable. 
I/O connections in the control panel (outside word) should be wired to the BOTTOM 
connectors on the PL-100 (J5 and J6). Specification for these signals are as follows: 
Specification  Definition 
Voltage  Load  24V maximum 
Current  GPO[0:1]  100mA max 
Protection  Fuse  PTC fuses to 100mA (GPO) 
Common 
ICMN/OCMN 
PWR or GND as wired on respective OPTOs 
Switch Time  GPO[0:1]  100 Microsecond (ON or OFF) 
PL-100 Connections 
Ethernet 
connection to BOA 
Manual Trigger for 
debugging 
Ethernet 
connection to PC 
I/O connections to 
BOA (A-BVS-IO8) 
I/O connections to 
control panel 