Installation manual
Version 02  teledynedalsa.com/ipd  21 
Output Specifications 
The BOA vision system provides two dedicated opto-isolated, solid state relay outputs 
and a separate dedicated light strobe (pin 2 of lamp connector). 
Specification  Definition 
Voltage (Vin)  Load  24V maximum 
Current  GPO[0:1]  100mA max (drives to OCMN when active) 
STRB  100mA max (drives to Vin when active) 
NOTE: Strobe timing is configured in the “Cam0” properties. 
Protection  Fuse  PTC fuses to 100mA (GPO) & 100mA (STRB) 
Common pin  Out  PWR or GND 
Switch Time  ON  10 Microsecond 
OFF  50 Microseconds 
The active polarity of each output is configured in the Sherlock Embedded Client 
application. 
To connect with an NPN input source, connect the camera output (pin 4 or 6) to the 
NPN source input and the camera common output (pin 8) to GND. When the camera 
output turns ON, the opto switch closes and OUTX = 0 (current flows through load) 
To connect with an PNP input source, connect the camera output (pin 4 or 6) to the 
PNP source input and the camera common output (pin 8) to PWR. When the camera 
output turns ON, the opto switch closes and OUTX = output common. 
Output Diagram 