Installation manual
Version 02  teledynedalsa.com/ipd  12 
Ethernet and I/O Setup with Lamp 
1. Connect the M12-8 male end of the Ethernet cordset (A-BVS-E8S-X) to the M12-8 
female connector labeled “LAN” on the camera. 
2. Connect the RJ45 end of the Ethernet cordset to the RJ45 connector labeled 
“CAM LAN” on the Panel Link breakout module (A-BVS-PL-100) 
3. Connect the RJ45 labeled “LAN” on the breakout module to the controlling PC, 
PLC or the factory LAN 
4. Connect camera PWR, GND and I/O from the control panel to the breakout screw 
terminals. 
5. Connect the M12-8 male end of the IO-PWR cordset (A-BVS-IO8S-X) to the M12-
8 female connector on the camera labeled “I/O PWR” 
6. Connect the open-ended wires of the IO-PWR cordset to their respective 
connections on the breakout module. 
BOA System 
A-BVS-E8S-X 
A-BVS-PL-100 
Setup Computer, PLC 
or Factory Network 
Cat5 Cable 
A-BVS-IO8S-X 
LED Lamp 
A-BVS-L5S-X 