Technical data
www.tridonic.com
2
Subject to change without notice.
Data sheet 08/13-LC007-8
LED control gear
Compact dimming
Specific technical data
Type Output Tolerance Typ. power Output voltage range Max. output current Operating
temperature ta
LCAI 050/1050 N020 DALI
350 mA ±6 % 25 W 2 – 74 V – -25 ... 50 °C
500 mA ±5 % 35 W 2 – 72 V – -25 ... 50 °C
700 mA ±5 % 50 W 2 – 71 V – -25 ... 50 °C
900 mA ±5 % 50 W 2 – 55 V – -25 ... 45 °C
1,050 mA (default) ±5 % 50 W 2 – 48 V – -25 ... 45 °C
48 V ±5 % 50 W – 1,050 mA -25 ... 45 °C
PHASED OUT