Note
T5 fl uorescent lamps should be inserted so that the lamp
stamps are on the same side. The lamp stamp should be
at the bottom (“cold spot”) with a vertical burning position.
In the event of non-compliance, the lamp wattage data can
uctuate greatly. In any case, the function (as well as the re-
quirements for evenness) should be checked at all dimmer
settings using a sample setup.
Correct:
The lamp cables are twisted and laid close to the respec-
tive lamps. The overlapping of the three lamp current
circuits on the right is minimized.
Incorrect:
The lamp cables of all ECGs are laid together and they also
form overlapping lamp current circuits.
Three 2-lamp ECGs