DAKE 3-PHASE DURA PRESS Models: Force 40, 70, 100 INSTRUCTIONAL MANUAL *Force 40 shown. May be slight differences* WARNING! Read and understand all instructions and responsibilities before operating. Failure to follow safety instructions and labels could result in serious injury. Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 Phone: 800.937.3253 www.dakecorp.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com TABLE OF CONTENTS DAKE STANDARD LIMITED WARRANTY ................................................................. 2 RETURN & REFUND POLICY .................................................................................... 4 SAFEGUARDING THE POINT OF OPERATION ........................................................ 5 SPECIFICATIONS ..............................................................................................
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com DAKE STANDARD LIMITED WARRANTY Finished Machines Dake warrants to the original purchaser the finished machine manufactured or distributed by it to be free from defects in material and workmanship under normal use and service within 1 year (12 months) from the delivery date to the end user.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Warranty Exceptions: The following conditions are not applicable to the standard limited warranty: (a) Part installation or machine service was not completed by a certified professional, and is not in accordance with applicable local codes, ordinances and good trade practices.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com RETURN & REFUND POLICY Thank you for purchasing from Dake! If you are not entirely satisfied with your purchase, we are here to help. Returns All Dake manufactured / distributed machines, parts and couplings include a 30-day return option. These policies are valid from the date of final shipment to the end user. To be eligible for a return, the item must be unused and in the same condition as received.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com SAFEGUARDING THE POINT OF OPERATION ANSI B11.2 - Hydraulic Power Presses Safety Requirements for Construction, Care, and Use It is important that Dake press users have a clear understanding of their responsibility involving the care and use of their Dake hydraulic press, including point-of-operation safe guards.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Specifications Model Number Capacity Horsepower Voltage Width between uprights Width between table channels Min. ram to table Max.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com SAFETY This is the safety alert symbol. When you see this symbol on your press be alert to the potential for personal injury. − Keeps safety labels in good condition and replace missing or damaged labels. If labels are needed send a request to Dake. Follow recommended precautions and safe operating practices.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Additional Warnings: • • • • • • • • Operator must never place hands in the area of the ram during pressing operations. Do not use the press for pulling A machine not subject to maintenance and periodical structural inspection is a danger for the operator and all persons working nearby. It is forbidden to tamper with, modify, or elaborate parts of the machine that alter its regular operation.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com • • Before handling the machine, it is necessary to use special lifting equipment whose maximum lifting capacity is greater than the weight of the press. Press weight can be found in the “Specifications” section of this manual. Lifting straps must be positioned as shown below. The manufacturer is no responsible for damage to the machine while loading or unloading the press.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Electrical Connection Only a certified electrician that follows local and state laws is authorized to perform any type of electrical connection on this press. The electrical power supply voltage must be made in compliance with local and state laws. − This machine is dual voltage 220V 3-phase / 440V 3-phase. The amp rating for voltages are in the table below. Voltage 220V, 3-phase 440V, 3-phase • • • • • Amp Rating 6.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Filling the Pump Unit To fill the pumping unit, use exclusively the oils indicated in the table or equivalent. The environmental conditions must be considered before purchasing oil. To transfer the oil from the container to the tank use an external filler to prevent the introduction of foreign material or liquids at the time of filling. Amount of oil for each press: 40 Ton 70 Ton 100 Ton 10.5 Gallons 10.5 Gallons 15.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Priming the Pump Before starting the machine for the first time it is necessary to prime the pump. 1. Check that all the valves and distributors are in the rest position. 2. Jog the start button (electric motor), when the unit emits a dull sound with no jumps and the sound of the pump is constant. 3. If the sound is uneven or bubbly there is air in the pump still. Repeat step 2 if this occurs. 4.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Operating Temperature After the machine has been operating at full rate check that the oil temperature does not exceed 140°F. If it does exceed 140°F check that the oil used is not too viscous and replace with more suitable oil if this is the case. MAINTENANCE Routine maintenance operation must be carried out by authorized and trained personnel.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com PARTS LIST Electrical Box Components: 1 2 3 4 5 Item Description 1 2 3 3 3A3 4 5 5B 6 6A Contactor Transformer Overload 220-volt Overload 440-volt N.O.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.
Dake Corporation 1809 Industrial Park Dr Grand Haven, MI 49417 www.dakecorp.com Please contact factory for current prices. ORDER INFORMATION Parts are available for direct purchase from Dake or through a distributor. When placing a parts order, you will need to provide the part number, name of part, and model number. All parts shipped F.O.B. Factory in Grand Haven, MI. DEACTIVATING THE MACHINE If the machine is not going to be used for a long period of time it is recommended that you so the following: 1.