User`s manual
23
24
Item
Decoration panel
Fresh air intake kit
Sealing member of air discharge outlet
Panel spacer
Wiring adaptor for electrical appendices
*
2
Installation box for adaptor PCB
Replacement long-life filter
Remote controller
Wired type
*
1
Wireless type
Remote sensor (for indoor temperature)
Adaptor for wiring*
2
Notes:
*1. Wiring for wired remote controller should be obtained locally.
*2. Installation box for adaptor PCB (KRP1BA101) is necessary.
KDDQ44XA60
KDBH44BA60
KDBQ44BA60A
KRP4AA53
KRP1BA57
KRP1BA101
KRCS01-1B
BYFQ60B8W1
KAFQ441BA60
BRC1C61
BRC7E531W
Compact multi flow ceiling-mounted cassette type
1
3
2
4
5
6
7
8
9
10
No.
Direct installation type
Specifications Options
Options
Control system
Indoor unit
Outdoor unit
No.
1
2
Item
Air direction adjustment grille
Drain plug
No.
1
2
3
4
5
6
7
5-room centralised controller*
1
Wiring adaptor for time clock/remote controller
*
2
(Normal open pulse contact/normal open contact)
Titanium apatite photocatalytic air-purifying filter*
3
Air-purifying filter with photocatalytic deodorising function
*
3
Remote controller loss prevention chain
Suction grille
Insulation kit for high humidity
FDKS25/35EA
FDKS50C FDKS60C
Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. Time clock and other devices should be obtained locally.
*3. Filter is a standard accessory. It should be replaced approximately 3 years.
FTKS25/35D
KAF970A46
–
FTKS50/60/71F
KAF952B42
FTKS50B
–
KAF952A42
KDGF19A45
No.
1
2
3
4
Item
Central remote controller*
Unified on/off controller*
Schedule timer*
Interface adaptor
DCS302CA61
DCS301BA61
DST301BA61
Wall-mounted type
Wall-mounted type
Duct-connected type
Duct-connected type
Compact multi flow ceiling-mounted cassette type
Item
5-room centralised
controller
KRC72
Remote controller loss
prevention chain
KKF917A4
Air direction adjustment grille
KPW945A4
Drain plug
KKP937A4
Central remote controller
DCS302CA61
Unified on/off controller
DCS301BA61
Schedule timer
DST301BA61
Titanium apatite photocatalytic
air-purifying filter
KAF952B42
Notes: *1. One set includes 5 pieces for 5 units.
*2. One set includes 1 piece for 1 unit.
KRP413AB1S
KKF917A4
KDT25N50 KDT25N63KDT25N32
–
–
–
KRC72
Titanium apatite photocatalytic
air-purifying filter
KAF970A46
FDKS25/35CA
Note: * Interface adaptor (KRP928BB2S or DTA112BA51) is also required for each indoor unit.
–
KRP928BB2S DTA112BA51
2MKS40F
KPW937A4
3MKS50E
KKP937A4*
1
3MKS71E
KPW945A4
4MKS80E 5MKS100L
KPW5E112
KKP945A4*
2
Liquid (flare)
Gas (flare)
Drain
Compact multi flow ceiling-mounted cassette type
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Model name
Power supply
Airflow rate (H)
Sound level* (H/L)
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping
connections
Heat insulation
dB (A)
mm
kg
mm
Model
Colour
Dimensions (H x W x D)
Weight
mm
kg
Panel
(option)
FFQ35BV1B
10.0 (353)
32/25
FFQ50BV1B
12.0 (424)
36/27
FFQ60BV1B
15.0 (530)
41/32
FFQ25BV1B
9.0 (318)
29.5/24.5
1 phase, 220-240 V, 50 Hz
2 steps
Microcomputer control
286 x 575 x 575
17.5
ø6.4
VP20 (External Dia. 26/Internal Dia. 20)
Both liquid and gas pipes
BYFQ60B8W1
White
2.7
ø9.5 ø12.7
55 x 700 x 700
Measurement conditions
1. Data is based on the following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 5m for 2MKS40FV1B, 4MKS80ESG and
5MKS100LSG; piping length 7.5m for 3MKS50ESG and 3MKS71ESG.
2. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
m
3
/min (cfm)