Service manual
Indoor Unit Si06-305
124 Removal Procedure
5
Dismount the fixing
screw to remove the
pipe retaining plate of
the heat exchanger.
Push the pipe retaining
plate backward to
disengage hook, then
open the retaining plate
using straight edge of
screw-driver to remove
the plate.
Mounting screw M4 × 16
6
Remove the two
screws located at left
side of the heat
exchanger.
Mounting screw M4 × 16
7
Pull forward left side of
the heat exchanger ,
slide to right to
disengage hook and
remove the heat
exchanger.
Caution!
When removing or re-
installing heat exchanger, be
sure to wear protective gloves
or wrap heat exchanger with
cloths. (Fins can cut fingers.)
Step Procedure Points