Specifications

IM 938-4 / Page 23 of 42
Premium (Programmable) Digital
Touchpad Control Features
LED with
Program
Setting
Display
8- Push
Button
Display
Inputs
9-LED
Indicators
Application
The PTAC Digital Control is used to control a PTAC Unit
that includes both an integral air conditioner and a source of
heat.
The Digital Control is operated with a Touchpad.
Inputs and Outputs
Indoor coil sensor, (ICS)
Outdoor coil sensor, (OCS)
Indoor air sensor, (IAS)
Outdoor air sensor, (OAS)
Remote T’stat, T’STAT (RCWYBG)
Heat Fan Lock Out (HFLO)
Power supply: (24VAC)
Line voltage input, (L1, L2)
Indoor fan standby voltage, (L1STB L2STB)
Control selection: (LUI, T’STAT
Model selection: (AC/E, HP, HP/E)
Time delay bypass, (TEST)
Indoor off fan cycle: (FAN, OFF CYCLE–10, 20,
30, 1 HR)
Outputs
Compressor output, COM
Indoor fan, BLOWER LO, HI
Outdoor fan, OUTDOOR FAN
Electric heater, ELE
Reversing valve, REV VALVE
User Interface
The user will by default control the Electronic Controller via
the touchpad. The user can select with a jumper for the unit
to receive commands from a Remote Thermostat.
Table 3: Keys and Indicators Labels
ON/OFF, FAN SPEED, MODE,
8 Push Buttons
FAN MODE, SLEEP, PROG-ON/OFF
Temp buttons: for
Temp UP and for Temp DOWN
9 LED Indicators
SLEEP, COOL, COOL/DRY, FAN,
HEAT, HIGH, LOW, CYCLE, CONT.
LED 2 Digit Displays No Label
Display Function Legend
Tr = Room Temperature
hI = High Room Temperature
Lo = Low Room Temperature
LA = Low Ambient Lockout
= Secondary (Slave) Unit Touchpad Display - Indicates
Unit is Controlled by a Master. Occurs when Slave
Control Select Jumper is on SEC Pins
rT = Remote Thermostat Control
tP = Touchpad Control
t = Time
Ts = Temperature Setpoint
Rf = Room Freeze Condition
CF = Coil Freeze Protection
F = Fahrenheit
C = Celsius
LC = Control Lockout Mode Turned ON
nL = Control Lockout Turned OFF
Premium, Programmable Digital Touchpad
with Automatic Changeover from Cooling
to Heating & Heating to Cooling
AUTO
Available with the Programmable LUI (668003802) and Pre-
mium Board (667997303) only. The Auto-Changeover board
has a new control set with a touchpad label that shows,
“AUTO”. The Auto Changeover control provides:
Auto changeover from heat to cool and vice versa
LED's from top down that read: Sleep, Cool, Auto, Fan,
and Heat