Specifications
14
VAM-FA
VAM800FA
SPECIFICATIONS
Heat reclaim ventilation
VENTILATION
VAM150FA8VE VAM250FA8VE VAM350FA8VE VAM500FA8VE VAM650FA8VE VAM800FA8VE VAM1000FA8VE VAM1500FA8VE VAM2000FA8VE
Power input -
50Hz
heat exchange mode
nom.
ultra high/
high/low
kW
0.116/
0.100/0.056
0.141/
0.112/0.062
0.194/
0.175/0.111
0.212/
0.189/0.118
0.380/
0.325/0.227
0.451/
0.400/0.346
0.469/
0.432/0.349
0.864/
0.758/0.655
0.953/
0.767/0.653
bypass mode nom.
ultra high/
high/low
kW
0.116/
0.100/0.056
0.141/
0.112/0.062
0.194/
0.175/0.111
0.212/
0.189/0.118
0.380/
0.325/0.227
0.451/
0.400/0.346
0.469/
0.432/0.349
0.864/
0.758/0.655
0.953/
0.767/0.653
Power input -
60Hz
heat exchange mode
nom.
ultra high/
high/low
kW
0.117/
0.099/0.056
0.138/
0.119/0.062
0.226/
0.214/0.120
0.253/
0.232/0.125
0.432/
0.384/0.251
0.514/
0.471/0.408
0.571/
0.537/0.419
0.981/
0.929/0.754
1.017/
1.021/0.779
bypass mode nom.
ultra high/
high/low
kW
0.117/
0.099/0.056
0.138/
0.119/0.062
0.226/
0.214/0.120
0.253/
0.232/0.125
0.432/
0.384/0.251
0.514/
0.471/0.408
0.571/
0.537/0.419
0.981/
0.929/0.754
1.017/
1.021/0.779
Temperature
exchange
eciency -
50Hz
ultra high % 74 72 75 74 75
Enthalpy
exchange
eciency -
50Hz
cooling ultra high %
58 61 58 60 61
Operation mode Heat exchange mode / Bypass mode / Fresh-up mode
Heat exchange system
Air to air cross ow total heat (sensible + latent heat) exchange
Heat exchange element
Specially processed non-ammable paper
Casing
material Galvanised steel plate
Dimensions
unit
heightxwidthxdepth
mm 285x776x525 301x828x816 364x1,004x868
364x1,004x1,156
726x1,514x868
726x1,514x1,156
Weight
unit kg 24 33 48 61 132 158
Fan
type
Sirocco fan
air ow rate -
50hz
heat exchange
mode/bypass mode
ultra high/
high/low
kW
150/
150/110
250/
250/155
350/
350/230
500/
500/350
650/
650/500
800/
800/670
1,000/
1,000/870
1,500/
1,500/1,200
2,000/
2,000/1,400
air ow rate -
60hz
heat exchange
mode/bypass mode
ultra high/
high/low
kW
150/
150/110
250/
250/145
350/
350/210
500/
500/300
650/
650/300
800/
800/670
1,000/
1,000/800
1,500/
1,500/1,200
2,000/
2,000/1,400
external static
pressure - 50hz
ultra high/high/low
Pa 69/39/20 64/39/20 98/70/25 98/54/25 93/39/25 137/98/49 157/98/78 137/98/49 137/78/59
external static
pressure - 60hz
ultra high/high/low
Pa 98/54/24 98/54/20 142/85/15 147/54/20 162/69/34 225/118/69 196/108/69 206/118/69 196/88/69
Fan motor
output 50 hz W 30 90 140 230
Sound
pressure
level - 50Hz
heat exchange
mode
ultra high/high/low dBA
27 / 28.5/26 /
27.5/20.5 / 21.5
28 / 29/26 /
27/21 / 22
32 / 34/31.5 /
33/23.5 / 26
33 / 34.5/31.5 /
33/24.5 / 26.5
34.5 / 35.5/33 /
34/27 / 28
36 / 37/34.5 /
36/31 / 32
36 / 37/35 /
36/31 / 32
39.5 / 41.5/38 /
39/34 / 36
40 / 42.5/38 /
41/35 / 37
bypass mode ultra high/high/low dBA
27 / 28.5/26.5 /
27.5/20.5 / 21.5
28 / 29/27 /
28/21 / 22
32 / 34/31 /
32.5/24.5 / 26.5
33.5 / 34.5/32.5 /
33.5/25.5 / 27.5
34.5 / 35.5/34 /
35/27 / 28.5
36 / 37/34.5 /
36/31 / 33
36 / 37/35.5 /
36/31 / 32
40.5 / 41.5/38 /
39/33.5 / 36
40 / 42.5/38 /
41/35 / 37
Sound pressure
level - 60Hz
heat exchange mode
ultra high/high/low dBA 28.5/26.5/19 29.5/26/19.5 34.5/32/22 34/31/24 36/33/27 37/35/30 40.5/38/33 41/38/35
bypass mode ultra high/high/low dBA 28/27/20 29/27/20.5 34.5/33/22 35/33/24 35.5/34/27 37/35/31 40.5/38/33 41/38/35
Operation
range
min. °CDB -15
max. °CDB 50
relative humidity % 80% or less
Connection duct diameter
mm 100 150 200 250 350
Piping
connections
drain -
Insulation material Self-extinguishable urethane foam
Power supply phase/frequency/voltage Hz/V 1~/50/60/220-240/220
(1) Operation sound is measured at 1.5m below the center of the body. (2) Normal amplitude, input and eciency depend on the mentioned conditions. (3) Sound values are measured in an anechoic chamber. Operating sound level generally becomes
higher than this value depending on the operating conditions, reected sound, and peripheral noise. (4) The specications, designs and information here are subject to change without notice.