User`s manual
SPECIFICATIONS
/s
3433
OUTDOOR UNITS
Note: Specifications are based on the following conditions;
• Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
• Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
• Equivalent piping length: 7.5 m
• Level difference: 0 m
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During
actual operation, these values are normally somewhat higher as a result of ambient conditions.
• Refrigerant charge is required.
Heat Pump
MODEL
Power supply
Cooling capacity
Capacity control %
Motor output
Type
m
3
/min
Casing colour
Compressor
mmDimensions (H x W x D)
Kcal/h
Heating capacity
Kcal/h
1-phase, 230–240 V, 50 Hz
24 to 100
Hermetically sealed scroll type
1,345 x 900 x 320
kgMachine weight 125
Liquid
Piping connections
ø9.5 (Flare)
Gas
kW
mm
ø15.9 (Flare)
dB(A)Sound power
Operation range
kgCharge
69
Refrigerant
Type R-410A
-5 to 46
-20 to 15.5
68 71
12,0009,600 13,300
RXYMQ4PV4A RXYMQ5PV4A RXYMQ6PV4A
ø19.1 (Brazing)
dB(A)
Sound level (Cooling/Heating)
51/5350/52 53/55
kW
Heating
Cooling
°CWB
°CDB
Heating
Cooling
13,80010,800 15,500
Btu/h
Btu/h
47,80038,200 52,900
54,60042,700 61,400
kW
kW
14.011.2 15.5
16.012.5 18.0
Power consumption
3.972.95 4.44
4.093.27 4.82
4.0
106
3.02.5 3.5
Ivory white (5Y7.5/1)
Airflow rate
1,766 /s
INDOOR UNITS
Connection unit series indoor units
Ceiling Suspended Cassette Type
kW
(*1)
(*2)
Kcal/h
(*1)
Power supply
8.3
7,100
1-phase, 220-240 V, 50 Hz
Btu/h
(*1)
28,300
kW
Kcal/h
Heating capacity (Max.)
9.0
7,700
Btu/h 30,700
Indoor unit
Airflow rate (H/L)
Sound power (H)
Casing
dB(A)
mmDimensions (H
X
W
X
D)
kgMachine weight
56
Piping
connections
Liquid
Gas
Drain
VP 20 (External Dia. 26/Internal Dia. 20)
25
White(10Y9/0.5)
316/233
165
X
895
X
895
9.5 (Flare)
15.9 (Flare)
11.6
10,000
39,600
12.5
10,800
42,700
59
31
483/350
230
X
895
X
895
14.5
8.0 11.2 14.0
12,500
49,500
14.0
12,000
47,800
60
Sound level (H/L)
dB(A) 40/35 43/38 44/39
31
533/383
230
X
895
X
895
mm
Cooling capacity
MODEL
Indoor unit
Connection unit BEVQ71MAVE
FXUQ71MAV1
BEVQ100MAVE
FXUQ100MAV1
BEVQ125MAVE
FXUQ125MAV1
Note : Specifications are based on the following conditions ;
•Cooling:
(*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB.(*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
•Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.
•Equivalent piping length: 7.5 m •Level difference: 0 m
•C
apacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for details.)
•Sound level: (FXLQ-MA,FXNQ-MA)
Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
(FXUQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m below the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
* A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data for details.
* If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other series, cooling/heating switchover will
not be possible using the remote controller of the Connection unit series indoor units. However, if the remote controller of an indoor unit from the other series is set
as a master remote controller, cooling/heating switchover will be possible.
* If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable cooling/heating switchover.
* Group control between Connection Unit series equipment within one system is possible. However, group control with the other VRV indoor units is not possible.
kW
Power
consumption
0.169
0.189
0.278
0.298
0.278
0.298
Cooling
Heating
m
3
/min 19/14 29/21 32/23
230 V
Floor Standing Type/Concealed Floor Standing Type
FXLQ
FXNQ
FXLQ20MAVE
2.3
7,800
2,000
8,500
FXLQ:Ivory white (5Y7.5/1) / FXNQ:Galvanised steel plate
2,200
Heating capacity
kW
Btu/h
kcal/h
Casing
Airflow rate (H/L)
/s 116/100
600
X
1,000
X
222
25.0
6.4
12.7
21O.D.
2.2
FXLQ25MAVE
2.9
9,900
2,500
10,900
2,800
116/100
600
X
1,000
X
222
25.0
6.4
12.7
2.8
FXLQ32MAVE
3.7
12,600
3,200
13,600
3,400
133/100
600
X
1,140
X
222
30.0
6.4
12.7
3.6
FXLQ40MAVE
4.7
16,000
4,000
17,100
4,300
183/141
600
X
1,140
X
222
30.0
6.4
12.7
4.5
FXLQ50MAVE
5.8
19,800
5,000
6.3
21,500
5,400
233/183
600
X
1,420
X
222
36.0
6.4
12.7
5.6
FXLQ63MAVE
FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
7.3
24,900
6,300
8.0
27,300
6,900
266/200
600
X
1,420
X
222
610
X
930
X
220 610
X
930
X
220 610
X
1,070
X
220 610
X
1,070
X
220 610
X
1,350
X
220 610
X
1,350
X
220
36.0
19.0 19.0 23.0 23.0 27.0 27.0
9.5
15.9
7.1
2.5 3.2 4.0 5.0
37/34 37/34 37/34 40/35 41/36 42/37
1-phase, 220-240 V/220 V, 50/60 Hz
Sound level (H/L)
dB(A)240 V
0.049 0.049 0.090 0.090 0.110 0.110
0.049 0.049 0.090 0.090 0.110 0.110
m
3
/min 7/6 7/6 8/6 11/8.5 14/11 16/12
kW
Power
consumption
Cooling
Heating
MODEL
Power supply
Cooling capacity
kW
(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Dimensions
(H
X
W
X
D)
Machine weight
mm
FXLQ
FXNQ
kg
FXLQ
FXNQ
Piping
connections
Drain
Liquid (Flare)
Gas (Flare)
mm