Service manual
6L(1 7URXEOHVKRRWLQJE\,QGLFDWLRQRQWKH5HPRWH&RQWURO
7URXEOHVKRRWLQJ
³JA´2XWGRRU8QLW0DOIXQFWLRQRI'LVFKDUJH3LSH3UHVVXUH
6HQVRU
5HPRWH&RQWURO
'LVSOD\
JA
$SSOLFDEOH
0RGHOV
5;<4a0
0HWKRGRI
0DOIXQFWLRQ
'HWHFWLRQ
0DOIXQFWLRQLVGHWHFWHGIURPWKHSUHVVXUHGHWHFWHGE\WKHKLJKSUHVVXUHVHQVRU
0DOIXQFWLRQ
'HFLVLRQ
&RQGLWLRQV
:KHQWKHGLVFKDUJHSLSHSUHVVXUHVHQVRULVVKRUWFLUFXLWRURSHQFLUFXLW
6XSSRVHG
&DXVHV
'HIHFWRIKLJKSUHVVXUHVHQVRUV\VWHP
&RQQHFWLRQRIORZSUHVVXUHVHQVRUZLWKZURQJFRQQHFWLRQ
'HIHFWRIRXWGRRUXQLW3&ERDUG
7URXEOHVKRRWLQJ
*9ROWDJHPHDVXUHPHQWSRLQW
*5HIHUWRSUHVVXUHVHQVRUSUHVVXUHYROWDJHFKDUDFWHULVWLFVWDEOHRQ3
(V2806)
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
The
relationship
between the ∗1
VH and high
pressure is normal (see
∗2) when voltage is
measured between X46A
pins (1) and (3) of
outdoor unit PC
board (A1P)
(see ∗1).
Replace the high pressure sensor.
Connect the high pressure sensor
and turn on again.
NO
NO
Replace outdoor unit PC board
A1P.
YES
YES
The high pressure
sensor is connected to
X46A of outdoor unit
PC board (A1P).
Outside unit PC board A2P
+5V
X46A
Red
Black
White
GND
*2 Measure DC voltage here.
Low pressure sensor
Microcomputer
A/D input
4
3
2
1
(V2807)