148 Service Diagnosis
5.1.7 Outdoor Unit Fan System Check
Check No.9 DC motor
5.1.8 Power Supply Waveforms Check
Check No.10 Measure the power supply waveform between pins 1 and 3 on the terminal board, and check
the waveform disturbance.
Check to see if the power supply waveform is a sine wave (Fig.1).
Check to see if there is waveform disturbance near the zero cross (sections circled in Fig.2)
5.1.9 Inverter Units Refrigerant System Check
Check No.11
Check the outdoor unit fan system.
(R2857)
Outdoor unit fan running?
Fan motor lead wire
connector disconnected?
Outdoor unit fan system
functioning.
Go to Check No. 15.
NO
NO
YES
YES
Reconnect.
[Fig.1] [Fig.2]
Discharge pressure check
Replace compessor.
Open the stop valve.
Replace the pipe installed at
the site.
Clean.
Replace the compressor.
At the heat exchanger
and air filter dirty?
Is the stop valve open?
Is the connection
pipe deformed?
High
YES
YES
NO
NO
NO
YES
YES
NO