Specifications

Control Specification SiBE06-708
42 Function and Control
25/35 class
50 class
Frequency
Compressor
Four way valve
Fan
Electronic expansion
valve opening
ON
OFF
ON
OFF
ON
OFF
0Hz
5sec.
350pulse 450pulse450pulse
Initial opening
PI control
5sec.
50sec.50sec. 660sec.
60sec.
74Hz
86Hz
30Hz
(R6930)
60sec.
Outdoor temp. < 0˚C
Outdoor temp. 0˚C
Frequency
Compressor
Four way valve
Fan
Electronic expansion
valve opening
ON
OFF
ON
OFF
ON
OFF
0Hz
55Hz
90Hz
5sec.
450pulse
Initial opening
PI control
5sec.
30sec.
60sec. 460 sec. (Max. limit)
120sec.
(R6931)
Outdoor temp. 0˚C
Outdoor temp. < 0˚C