Service manual

Check SiBE06-708_C
134 Service Diagnosis
5.11 Outdoor Fan System Check
Check No.19 DC motor
5.12 Main Circuit Short Check
Check No.20 25/35 class, RXS50K2V1B only
Note: Check to make sure that the voltage between (+) and (–) of the diode bridge (DB1) is approx.
0 V before checking.
Measure the resistance between the pins of the DB1 referring to the table below.
If the resistance is or less than 1 k, short circuit occurs on the main circuit.
RK(X)S25/35F2V1B
(R15001)
YES
YES
NO
NO
Outdoor fan system is functioning.
Check the outdoor fan system.
Go to Check No. 16.
Outdoor fan running?
Fan motor
lead wire connector
disconnected?
Reconnect the connector.
Negative (–) terminal of
tester (positive terminal
(+) for digital tester)
~
(2, 3)
+
(4)
~
(2, 3)
(1)
Positive (+) terminal of
tester (negative terminal
(–) for digital tester)
+
(4)
~
(2, 3)
(1)
~
(2, 3)
Resistance is OK. several k
~ several M
∞∞
several k
~ several M
Resistance is NG. 0 or
000 or
(R12412)
–~~+
1234
+
Tester