Service manual

3-32
12. OPTIONAL CONDITION SETTING MODE
<
Key operation to enter/exit
>
<Key operation in this mode>
Whenever the key is pressed, the indication changes.
Turn the power breaker OFF after the setting.
S
To set the chartless code (D code /H code):
Select "ON
" (indication of D/H code) or "OFF" (no indication of D/H code) on
the LED when the LCD displays "CHARTLS".
Whenever the or key is pressed, the indication of "ON
" or "OFF" is
changed.
Press the key to determine the setting.
To set the USDA sensor selection:
Select "1" or "2
" on the LED when the LCD displays "USdA1/2".
Whenever the or key is pressed, the indication of "1" or "2
" is changed.
H001
CHARTLESS CODE
INDICATION
SETTING
S
S
USDA SENSOR
1/2 SELECTION
SETTING
S
S
I/O ON I/O OFF
I/O
Power OFF
Unit OFF
All indication
lights on
(for 3 sec.)
Starting
preparation
(for 18 sec.)
1
Current
indication
(Operation state)
Circuit Breaker ON
Circuit Breaker OFF
after setting change
( OFF when no setting changed)
for 3 sec. for 3 sec. for 3 sec.
10
12 11
F. PTI
S. PTI
M. CHECK
Optional
Function
Setting
Basic Function
Setting
Optional
Condition
Setting
for 3 sec.
Press the key to determine the setting.
(see mode detail5-9)
H001 code is displayed when the control temperature does not lower by 3 ˚C
or more for every 4 hours in pull-down operation.
Select "1" ˚C ,"2" ˚C ,"3
" ˚C ,"4" ˚C ,"5" ˚C or "10" ˚C on the LED when the LCD
displays "H001".
Whenever the or key is pressed, the indication of the selection from
"1"˚C to "10" ˚C changes. Press the key to determine the setting.
Refer to page 3-66.