Service manual
Specifications SiBE12-816_D
29 Specifications
1.4 Heat Pump - Outdoor Unit
50 Hz, 220 - 240 V
Note:
1. The data are based on the conditions shown in the table below.
Model
2MXS40GV1B 2MXS40G2V1B
Cooling Heating Cooling Heating
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 1YC23ABXD 1YC23AGXD
Motor Output W 600 600
Refrigerant
Oil
Model FVC50K FVC50K
Charge L 0.45 0.45
Refrigerant
Type R-410A R-410A
Charge kg 1.20 1.20
Airflow Rate
HH
m³/min
36 32 36 32
H 33323332
L 30323032
HH
cfm
1,271 1,130 1,271 1,130
H 1,165 1,130 1,165 1,130
L 1,059 1,130 1,059 1,130
Fan
Type Propeller Propeller
Motor Output W 50 50
Starting Current A 5.9 5.9
Dimension (H
×
W
×
D) mm 550
×
765
×
285 550
×
765
×
285
Packaged Dimension (H
×
W
×
D) mm 612
×
906
×
364 612
×
906
×
364
Weight (Mass) kg 38 38
Gross Weight (Gross Mass) kg 43 43
Operation Sound dB(A) 47 48 47 48
Sound Power dB(A) 62 — 62 —
Piping
Connection
Liquid mm
φ
6.4
×
2
φ
6.4
×
2
Gas mm
φ
9.5
×
2
φ
9.5
×
2
Drain mm
φ
18
φ
18
Heat Insulation Both Liquid & Gas Pipes Both Liquid & Gas Pipes
No. of Wiring Connection 3 for Power Supply, 4 for Interunit Wiring 3 for Power Supply, 4 for Interunit Wiring
Max. Piping Length m
30 (for Total of Each Room) 30 (for Total of Each Room)
20 (for One Room) 20 (for One Room)
Min. Piping Length m 3 (for One Room) 3 (for One Room)
Amount of Additional Charge g/m 20 (20 m or more) 20 (20 m or more)
Max. Installation Height Difference m
15 (between Indoor Unit and Outdoor Unit) 15 (between Indoor Unit and Outdoor Unit)
7.5 (between Indoor Units) 7.5 (between Indoor Units)
Drawing No. 3D059050A 3D058721B
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling Heating Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB
5 m