Service manual

Code Indication on Remote Controller SiBE12-816_D
213 Service Diagnosis
4. Code Indication on Remote Controller
4.1 RA Indoor Unit - F(C)TXG, FTXS, FVXS, FLK(X)S,
FDK(X)S Series
4.2 SA Indoor Unit - FFQ Series
: Error code displays automatically and system stops.
Inspect and repair it.
: In the case of the shaded error codes, “inspection” is not displayed. The system
operates, but be sure to inspect and repair it.
Note: When there is a possibility of open phase power supply, also check power supply.
Error Codes Description Reference Page
00
Normal condition
A1
Indoor unit PCB abnormality 215
A5
Freeze-up protection control or heating peak-cut control 216
A6
Fan motor or related abnormality
AC motor (duct, floor / ceiling) 218
DC motor (wall, floor standing) 219
C4
Indoor heat exchanger thermistor or related abnormality 221
C7
Front panel open / close fault 222
C9
Room temperature thermistor or related abnormality 221
Error Codes Description Reference Page
00
Normal condition
A1
Indoor unit PCB abnormality 223
A3
Drain water level system abnormality 224
A6
Fan motor or related abnormality (See the Note below.) 226
AF
Drain system abnormality 227
C4
Indoor heat exchanger thermistor or related abnormality 228
C9
Room temperature thermistor or related abnormality 228
CJ
Remote controller thermistor abnormality 230
U5
Signal transmission error (between indoor unit and remote
controller)
231
U8
Signal transmission error (between MAIN remote controller and
SUB remote controller)
232
UA
Field setting abnormality 233