Service manual
Functions SiBE12-816_D
9 List of Functions
Category Functions
FFQ25/35/50B8V1B
2MXS40/50GV1B
2MXS40/50G2V1B
Category Functions
FFQ25/35/50B8V1B
2MXS40/50GV1B
2MXS40/50G2V1B
Basic
Function
Inverter (with Inverter Power Control)
{{
Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°CDB) —
10
~46
Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°CWB) —
–
15
~15.5
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control —
{
Titanium Apatite Photocatalytic
Air-Purifying Filter
——
Standby Electricity Saving — —
Compressor Oval Scroll Compressor — — Longlife Filter (Option)
{
—
Swing Compressor —
{
Air Filter (Prefilter)
{
—
Rotary Compressor — — Wipe-Clean Flat Panel — —
Reluctance DC Motor —
{
Washable Grille — —
Comfortable
Airflow
Power-Airflow Flap — — Filter Cleaning Indicator
{
—
Power-Airflow Dual Flaps — — MOLD PROOF Operation — —
Power-Airflow Diffuser — — Good-Sleep Cooling Operation — —
Wide-Angle Louvers — — Timer WEEKLY TIMER Operation — —
Vertical Auto-Swing (Up and Down)
{
— 72-Hour ON/OFF TIMER
{
—
Horizontal Auto-Swing (Right and Left) — — NIGHT SET Mode — —
3-D Airflow — — Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
—
COMFORT AIRFLOW Operation — — Self-Diagnosis (Digital, LED) Display
{{
Comfort
Control
Auto Fan Speed — — Wiring Error Check Function — —
Indoor Unit Quiet Operation — —
Anti-Corrosion Treatment of Outdoor
Heat Exchanger
—
{
NIGHT QUIET Mode (Automatic) — —
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{
—
OUTDOOR UNIT QUIET Operation
(Manual)
—
{
H/P, C/O Compatible Indoor Unit
{
—
2-Area INTELLIGENT EYE Operation — — Flexible Power Supply Correspondence — —
INTELLIGENT EYE Operation — — High Ceiling Application — —
Quick Warming Function
(Preheating Operation)
—
{
Chargeless — 20 m
Hot-Start Function
{
— Either Side Drain (Right or Left) — —
Automatic Defrosting —
{
Power Selection —
{
Operation Automatic Operation
{
— Remote
Control
5-Room Centralized Controller (Option) — —
Program Dry Operation
{
—
Remote Control Adaptor
(Normal Open Pulse Contact) (Option)
——
Fan Only
{
—
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Remote Control Adaptor
(Normal Open Contact) (Option)
——
Inverter POWERFUL Operation — — DIII-NET Compatible (Adaptor) (Option)
{
—
Priority-Room Setting — — Remote
Controller
Wireless (Option)
{
—
COOL / HEAT Mode Lock — — Wired
{
—
HOME LEAVE Operation — —
ECONO Operation — —
Indoor Unit ON/OFF Button — —
Signal Receiving Sign — —
R/C with Back Light — —
Temperature Display — —
Note:
{
: Holding Functions
— : No Functions