Service manual
SiBE12-816_D Functions
List of Functions 4
Category Functions
FFQ25/35/50B8V1B
2MKS40/50GV1B
2MKS40/50G2V1B
Category Functions
FFQ25/35/50B8V1B
2MKS40/50GV1B
2MKS40/50G2V1B
Basic
Function
Inverter (with Inverter Power Control)
{{
Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°CDB) —
10
~46
Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°CWB) — —
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control —
{
Standby Electricity Saving — —
Titanium Apatite Photocatalytic
Air-Purifying Filter
——
Compressor Oval Scroll Compressor — —
Swing Compressor —
{
Longlife Filter (Option)
{
—
Rotary Compressor — — Air Filter (Prefilter)
{
—
Reluctance DC Motor —
{
Wipe-Clean Flat Panel — —
Comfortable
Airflow
Power-Airflow Flap — — Washable Grille — —
Power-Airflow Dual Flaps — — Filter Cleaning Indicator
{
—
Power-Airflow Diffuser — — MOLD PROOF Operation — —
Wide-Angle Louvers — — Good-Sleep Cooling Operation — —
Vertical Auto-Swing (Up and Down)
{
— Timer WEEKLY TIMER Operation — —
Horizontal Auto-Swing (Right and Left) — — 72-Hour ON/OFF TIMER
{
—
3-D Airflow — — NIGHT SET Mode — —
COMFORT AIRFLOW Operation — — Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
—
Comfort
Control
Auto Fan Speed — — Self-Diagnosis (Digital, LED) Display
{{
Indoor Unit Quiet Operation — — Wiring Error Check Function — —
NIGHT QUIET Mode (Automatic) — —
Anti-Corrosion Treatment of Outdoor
Heat Exchanger
—
{
OUTDOOR UNIT QUIET Operation
(Manual)
—
{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{
—
2-Area INTELLIGENT EYE Operation — — H/P, C/O Compatible Indoor Unit
{
—
INTELLIGENT EYE Operation — — Flexible Power Supply Correspondence — —
Quick Warming Function
(Preheating Operation)
— — High Ceiling Application — —
Hot-Start Function — — Chargeless — 20 m
Automatic Defrosting — — Either Side Drain (Right or Left) — —
Operation Automatic Operation — — Power Selection —
{
Program Dry Operation
{
— Remote
Control
5-Room Centralized Controller (Option) — —
Fan Only
{
—
Remote Control Adaptor
(Normal Open Pulse Contact) (Option)
——
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Inverter POWERFUL Operation — —
Remote Control Adaptor
(Normal Open Contact) (Option)
——
Priority-Room Setting — — DIII-NET Compatible (Adaptor) (Option)
{
—
COOL / HEAT Mode Lock — — Remote
Controller
Wireless (Option)
{
—
HOME LEAVE Operation — — Wired
{
—
ECONO Operation — —
Indoor Unit ON/OFF Button — —
Signal Receiving Sign — —
R/C with Back Light — —
Temperature Display — —
Note:
{
: Holding Functions
— : No Functions